DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD0255190
Title:
EXPLORATORY INVESTIGATION OF TRANSPIRATION COOLING OF A 40 DEGREE DOUBLE WEDGE USING NITROGEN AND HELIUM AS COOLANTS AT STAGNATION TEMPERATURES FROM 1,295 DEGREES F TO 2,910 DEGREES F,
Corporate Author:
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION WASHINGTON D C
Report Date:
1961-05-01
Abstract:
An investigation of transpiration cooling was conducted in the preflight jet of the Langley Pilotless Aircraft Research Station at Wallops Island, Va. The model consisted of a double wedge of 40 degrees included angle having a porous stainless-steel specimen inserted flush with the top surface of the wedge. The tests were conducted at a free-stream Mach number of 2.0 for stagnation temperatures ranging from 1,295 F to 2,910 F. Nitrogen and helium were used as coolants and tests were conducted for values ranging from approximately 0.03 to 0.30 percent of the local weight flow rate. The data for both the nitrogen and helium coolants indicated greater cooling effectiveness than that predicted by theory and were in good agreement with the results for an 8 degree cone tested at a stagnation temperature of 600 F. The results indicate that the helium coolant, for the same amount of heat-transfer reduction, requires only about one-fourth to one-fifth the coolant flow weight as the nitrogen coolant. Author
Supplementary Note:
Supersedes NACA Research Memorandum L57F11, AD-138 635. Also available from NASA.
Pages:
0018
File Size:
0.00MB