DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADP007660
Title:
All-Optical Microwave Gain Measurements on MMIC Amplifiers,
Descriptive Note:
Corporate Author:
LIGHTWAVE ELECTRONICS CORP MOUNTAIN VIEW CA
Report Date:
1992-05-22
Pagination or Media Count:
5.0
Abstract:
All-optical swept-frequency measurement of the gain of two types of microwave integrated circuits, a feedback amplifier and a distributed amplifier, is demonstrated. A diode laser excites an on-chip photodetector and the circuit response is measured with electro-optic sampling. The only physical contact probes are DC bias probes for the circuit and the on-chip MSM photodetector. ne optically measured gains compare favorably to independent network analyzer measurements using contact probing. The integrated photodetector needed for signal generation is process compatible with MMIC technology, occupies a small space on the wafer, and requires no additional processing steps. Since the yield of the photodetector is very high compared to the MMICs, the all optical test is potentially a practical and low cost approach for RF monitoring of circuits.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE