Accession Number:

ADP005206

Title:

Design Considerations for Short Haul Cables,

Descriptive Note:

Corporate Author:

SIEMENS A G MUNICH (GERMANY F R)

Personal Author(s):

Report Date:

1986-11-01

Pagination or Media Count:

3.0

Abstract:

The requirements of safe installation and use even of long lengths, economic splicing and branching as well as reduction of cable types lead to only two designs The Maxibundle design for fiber counts from 4 to 24 and the Minibundle design for fiber counts from 20 to 100. With an expected average fiber content of 15 the first one will cover more than 50 of the needed cables. It leads to a one-operation cable, provides the fibers with a sufficient length margin and does not need steel wires as tensile elements. Author

Subject Categories:

  • Optics

Distribution Statement:

APPROVED FOR PUBLIC RELEASE