Accession Number:

ADP004602

Title:

Design of SC Cut 10 MHz H.Q. Crystals with G. Sensitivity Better Than 2.10(-10)/G,

Descriptive Note:

Corporate Author:

COMPAGNIE D'ELECTRONIQUE ET DE PIEZO-ELECTRICITE ARGENTEUIL (FRANCE)

Personal Author(s):

Report Date:

1984-04-02

Pagination or Media Count:

18.0

Abstract:

Several theoretical and experimental studies on the force-frequency effect have shown that the g sensitivity of a crystal resonator is directly related to the location and structure of the mounting support. This work has lead to the definition of a new design of crystal resonator having low sensitivity. The effects of both surface and body forces applied to the vibrating part of the crystal must be considered. In this paper, the details of this new design are presented. Statistical results show that g sensitivity between 3.10 to the minus 11th powerg and 2.10 to the minus 10th powerg on the worst axis are currently obtained on an industrial basis. These values are measured by a 2 g tip over test in all directions either with Phase Modulated Reflectometer which are also described at 5 and 10 MHz or in classical oscillators.

Subject Categories:

Distribution Statement:

APPROVED FOR PUBLIC RELEASE