Accession Number:

ADA639312

Title:

High Average Power Tests of a Crossed-Field Closing Switch

Descriptive Note:

Conference paper

Corporate Author:

HUGHES RESEARCH LABS MALIBU CA

Report Date:

1976-11-01

Pagination or Media Count:

7.0

Abstract:

A triode version of the crossed-field closing switch CFCS has been successfully tested at average powers of up to 800 kW 40 kA, 40 kV, 12 microsecond pulse width at 80Hz for burst durations of 30 s. Unlike most conventional spark gaps, the arc is initiated from a crossed-field glow discharge and occurs at random locations on a shot-to-shot basis. This uniformly disperses the heat loading and erosion over a relatively large electrode surface area which may then be cooled.

Subject Categories:

  • Electrical and Electronic Equipment

Distribution Statement:

APPROVED FOR PUBLIC RELEASE