Accession Number:

ADA629388

Title:

Composite Bone and Soft Tissue Loss Treated with Distraction Histiogenesis

Descriptive Note:

Journal article

Corporate Author:

ARMY INST OF SURGICAL RESEARCH FORT SAM HOUSTON TX

Report Date:

2010-01-01

Pagination or Media Count:

7.0

Abstract:

The purpose of this article is to describe the use of shortening and angulation to manage composite bone and soft tissue loss associated with combat-related type IIIB open tibia fractures. Four patients underwent placement of a software-driven circular fixator with acute shortening and angulation to manage composite bone and soft tissue loss. Frames were applied using the Rings First Method, and an induced deformity was created with the soft tissue defect within the concavity. Distraction histiogenesis was utilized to restore limb length and regenerate soft tissues. Three patients had healed fractures and mature regenerate allowing frame removal, while one remained in his frame for further consolidation. Mechanical alignment and limb length were restored in all patients. No major frame adjustments were required and all distracted soft tissues healed without complication. The article concludes that composite bone and soft tissue loss is effectively managed with distraction histiogenesis and the use of a software-driven circular fixator.

Subject Categories:

  • Anatomy and Physiology
  • Medicine and Medical Research
  • Weapons Effects (Biological)
  • Military Forces and Organizations

Distribution Statement:

APPROVED FOR PUBLIC RELEASE