DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA564300
Title:
Penetration of Aerosols Through Minicam Preconcentrator Tubes
Descriptive Note:
Final rept. Jan 2010-Sep 2011
Corporate Author:
ARMY EDGEWOOD CHEMICAL BIOLOGICAL CENTER APG MD RESEARCH AND TECHNOLOGY DIR
Report Date:
2012-06-01
Pagination or Media Count:
22.0
Abstract:
The principle goal of this study was to investigate the use of MINICAM preconcentrator tubes PCTs as aerosol sampling devices. A series of penetration tests was conducted with a low-volatility liquid aerosol challenge on PCTs preloaded with several candidate sorbent bed materials. The results of this study show that commercial MINICAM PCTs were effective collectors for aerosol particles with aerodynamic diameters greater than 1 m however, significant breakthrough occurred for sub-micron aerosols with all four sorbent materials tested. Based on these findings, the use of PCTs for aerosol sampling is acceptable over the restricted range of laboratory-generated aerosol challenges indicated in this report.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE