DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA551178
Title:
Measurement of Upconversion in Er:YAG via Z-scan
Descriptive Note:
Journal article
Corporate Author:
ARMY RESEARCH LAB ADELPHI MD
Report Date:
2011-10-01
Pagination or Media Count:
5.0
Abstract:
We demonstrate the use of the z-scan technique for measuring the upconversion coefficient in ErYAG. The upconversion coefficient is found to be linearly proportional to the concentration for samples of concentration 05-30 at. A fit to four samples at room temperature yields a value of Cup 2.0 - 0.5 x 10exp -17 cu cmsat. The coefficient at liquid-nitrogen temperatures is Cup 9.5 - 2.4 x 10exp -17 cu cmsat.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE