Accession Number:

ADA495953

Title:

Compact Microwave Cavity for Hydrogen Atomic Clock

Descriptive Note:

Conference paper

Corporate Author:

BEIJING INST OF RADIO METROLOGY AND MEASUREMENT (CHINA)

Report Date:

1991-12-01

Pagination or Media Count:

10.0

Abstract:

This paper gives a summary introduction to the compact microwave cavity used in the hydrogen atomic clock. Special emphasis is put on derivation of theoretical calculating equations of main parameters of the microwave cavity. A brief description is given of several methods for discriminating the oscillating modes. Experimental data and respective calculated values are also presented.

Subject Categories:

  • Test Facilities, Equipment and Methods

Distribution Statement:

APPROVED FOR PUBLIC RELEASE