A Comparison of the AC Breakdown Strength of New and Used Poly A-Olefin Oil to Transformer Oil (Preprint)

Descriptive Note:

Conference paper preprint

Corporate Author:

MISSOURI UNIV-COLUMBIA DEPT OF ELECTRICAL ENGINEERING

Personal Author(s):

Report Date:

2006-04-01

Pagination or Media Count:

6.0

Abstract:

The breakdown performance of an advanced synthetic dielectric coolant, poly-alpha olefin, is compared to conventional transformer oil over a range of temperatures from 10 to 50 deg. C. The poly-olefin oil is first benchmarked against conventional transformer oil, and then compared to poly-olefin oil that has been exposed to a large number of high-energy discharges in order to establish the effects of oil age on performance. The results obtained from the standard ANSI D877 testing procedure are then compared to the results of a modified test procedure.