Accession Number:

ADA426127

Title:

Size Reduction Research for the Universal Initiator CY2001 Report

Descriptive Note:

Final rept. Jan-Dec 2001

Corporate Author:

ARMY RESEARCH LAB ADELPHI MD SENSORS AND ELECTRON DEVICES DIRECTORATE

Personal Author(s):

Report Date:

2004-06-01

Pagination or Media Count:

27.0

Abstract:

We describe two aspects of miniaturization research for the proposed universal initiator UI system. The UI would combine functionality of the remote activation munitions system RAMS and the sympathetic detonation SYDET system. First, we discuss the results of a market survey of candidate display devices for UI, where we conclude that organic light emitting diode device technology is most appropriate. We also discuss twisted nematic liquid crystal diode device technology which is used in RAMS and SYDET. Second, we discuss possible size reduction in the quadrature detector of the radio frequency receiver used in the RAMS system, with emphasis on new parts and technologies. We show results of tests performed on a ceramic resonator that would allow significant size reduction in the receiver, and conclude that use of the ceramic device will result in an unacceptable loss in sensitivity of the receiver. The work was performed at the U.S. Army Research Laboratory in calendar year 2001.

Subject Categories:

  • Ammunition and Explosives

Distribution Statement:

APPROVED FOR PUBLIC RELEASE