Accession Number:

ADA416798

Title:

Domestic Preparedness Program: Phase 2 Sarin Vapor Challenge and Corn Oil Protection Factor (PF) Testing of Commercial Powered Air Purifying Respirator (PAPR) Systems and Cartridges

Descriptive Note:

Final rept. May-Sep 2000

Corporate Author:

EDGEWOOD CHEMICAL BIOLOGICAL CENTER ABERDEEN PROVING GROUND MD

Report Date:

2003-04-01

Pagination or Media Count:

22.0

Abstract:

Results of performance testing of commercial powered air purifying respirator PAPR systems and cartridges are described. Three series of tests were performed 1 breakthrough time determinations of cartridges against Sarin GB 2 GB vapor penetration determination of entire PAPR systems using manikin headform and simulated breathing and 3 corn-oil protection factor determinations of PAPR systems using human subjects. Results indicate that cartridges provide complete penetration resistance against 200 mgm3 GB challenge concentrations for 60 min, but unacceptably high levels of GB vapor and corn oil aerosol may penetrate into the breathing zone of the PAPRs.

Subject Categories:

  • Chemical, Biological and Radiological Warfare

Distribution Statement:

APPROVED FOR PUBLIC RELEASE