Accession Number:

ADA402900

Title:

Design of Spillway Tainter Gates

Descriptive Note:

Engineer manual

Corporate Author:

CORPS OF ENGINEERS WASHINGTON DC

Personal Author(s):

Report Date:

2000-01-01

Pagination or Media Count:

113.0

Abstract:

This manual provides guidance for the design, fabrication, and inspection of spillway tainter gates, trunnion girder, and trunnion girder anchorage for navigation and flood control projects. Load and resistance factor design LRFD criteria are specified for design of steel components. Allowable stress design ASD criteria are provided in EM ii 10-2-2105 and may be used only with prior approval of CECW-ET. Orthotropic shell, vertical framed, and stress skin-type tainter gates may be suitable in some locations but are not covered in this manual. Other types of control gates, including radial lock valves reverse tainter valves and sluice gates, may be referred to as tainter gates but also are not included in this manual.

Subject Categories:

  • Civil Engineering

Distribution Statement:

APPROVED FOR PUBLIC RELEASE