Accession Number:

ADA347533

Title:

Comparison of 100 Micron Transmission Cell and the 3M IR Card for FT-IR Analysis of Military Fluids

Descriptive Note:

Corporate Author:

JOINT OIL ANALYSIS PROGRAM PENSACOLA FLTECHNICAL SUPPORT CENTER

Report Date:

1998-01-01

Pagination or Media Count:

9.0

Abstract:

The 100 micron transmission cell is the current method of choice for automated FT-IR analysis of lubricating and hydraulic oils. The transmission cell requires cleaning after each sample and thus use of a solvent. This paper outlines the preliminary results of a comparison between the 100 micron cell and the 3Mcopyright IR Card microporous polyethylene substrate. Petroleum and polyol ester lubricating oils were used in the study. Statistical results and problems encountered are presented.

Subject Categories:

  • Lubricants and Hydraulic Fluids
  • Atomic and Molecular Physics and Spectroscopy

Distribution Statement:

APPROVED FOR PUBLIC RELEASE