Accession Number:

ADA329249

Title:

Millimeter Wave Reflectivity Measurement System (MRMS) Data Acquisition Controller Upgrade.

Descriptive Note:

Final rept. Feb 93-Dec 96,

Corporate Author:

WRIGHT LAB EGLIN AFB FL ARMAMENT DIRECTORATE

Report Date:

1996-12-16

Pagination or Media Count:

28.0

Abstract:

The Millimeter Wave Reflectivity Measurement System MRMS is used by researchers to investigate the basic phenomenology, to verify theoretical models, and to assess the effectiveness of actual countermeasures of various materials for target scattering at millimeter wave MMW frequencies. The data acquisition portion of the MRMS was constructed using a Hewlett-Packard HP 310 computer as the system controller. The data acquisition controller was difficult to operate because its operating system and disk formats were quite different from personal computer PC operating system the engineer or scientist was accustomed to using. Off-the-shelf PC products are readily available. There is extensive in-house programming expertise for the PC which is not the case with the HP computer. The limitations with the HP computer-based controller hampered the ability of the MRMS to be an effective tool and meet the needs of the engineer and scientist. The decision was made to switch to a PC-based controller. This would provide software and hardware maintainability, portability, and upgradability ease of use by engineers and scientists thus, improving the MRMS capability to be an effective research and verification tool. This report describes the development of the PC-based data acquisition controller for the MRMS.

Subject Categories:

  • Countermeasures
  • Radiofrequency Wave Propagation
  • Computer Programming and Software

Distribution Statement:

APPROVED FOR PUBLIC RELEASE