Accession Number:

ADA310564

Title:

Investigation of Bonded Plastic Tape for Lining Filament-Wound Fiber-Glass Cryogenic Propellant Tanks.

Descriptive Note:

Technical note,

Corporate Author:

NATIONAL AERONAUTICS AND SPACE ADMINISTRATION CLEVELAND OH LEWIS RESEARCH CEN TER

Report Date:

1966-01-01

Pagination or Media Count:

46.0

Abstract:

The use of filament-wound fiber-glass liquid-hydrogen propellant tank structures should result in a considerable weight savings compared to conventional metal tanks providing that a suitable internal liner can be developed. This report investigates the use of plastic tape liners bonded to the inner surface of the filament-wound structure. The compatibility of liners, made of Teflon and Mylar tape, with respect to the filament-wound shell was studied experimentally using liquid hydrogen and theoretically using an analytical technique derived in this report. The investigation shows for bonded liners used at the temperature of liquid hydrogen normal boiling point 20 deg K that Teflon is incompatible with the filament-wound structure and Mylar is limited.

Subject Categories:

  • Plastics
  • Liquid Rocket Propellants
  • Mechanics

Distribution Statement:

APPROVED FOR PUBLIC RELEASE