Abstract:

A summary of the operating parameters and results from the three tests conducted during the Trial Burn is provided in Table ES-1. The SQI was in compliance with federal and state guidelines for destruction and removal efficiency DRE, particulate, hydrogen chloride HCL, and carbon monoxide CO emission while processing a maximum rate of 179.9 lbmin 18 gpm of 100 Basin F liquid at an average incinerator temperature 1835 deg F. jg p. 15--v.1