DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA288888
Title:
Infrared Multispectral Sensor Program, Phase 2. Field Measurements, Analysis and Modeling. Volume 1. Fourier Transform Spectrometer Sensor Characterization.
Descriptive Note:
Final technical rept. 1 Jan-31 Dec 93,
Corporate Author:
ENVIRONMENTAL RESEARCH INST OF MICHIGAN ANN ARBOR
Report Date:
1994-05-01
Pagination or Media Count:
158.0
Abstract:
A data collection sensor based on a Bomem Fourier transform spectrometer was used to measure infrared multispectral targetbackground signatures. This report describes the data collection sensor, including data processing software for quick look data analysis, gives the sensor characteristics test procedures and their results, and analyzes the effect of the sensor characteristics on the quality of the measured signatures.The sensor gives a very high level of performance including noise equivalent spectral radiances of 1 nWsq cm sr cm-1 in the MWIR 3 to 5 micrometers region and 6 nWsq cm sr cm-1 in the LWIR 8 to 12 micrometers region, a relative calibration accuracy to less than 0.25 above 4 micrometers, and spectral band-to-band correlation preservation greater than 0.9999 in the LWIR, and greater than 0.9995 between MWIR and LwIR and within the 4 to 5 micrometers region of the MWIR.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE