Accession Number:

ADA281008

Title:

Average and Local Heat Transfer for Crossflow Through a Tube Bank

Descriptive Note:

Corporate Author:

WESTINGHOUSE ELECTRIC CORP PITTSBURGH PA ATOMIC POWER DIV

Report Date:

1954-01-01

Pagination or Media Count:

14.0

Abstract:

Heat-transfer coefficients have been determined for a crossflow tube bank by the use of heat-and-mass-transfer techniques for the Reynolds-number range of 35,000 to 80,000. The average heat-transfer coefficients agree favorably with extrapolations of existing data. The local coefficient variations from the average were as great as 80 per cent and -55 per cent.

Subject Categories:

  • Thermodynamics

Distribution Statement:

APPROVED FOR PUBLIC RELEASE