Re-Evaluating the DSI Contaminated Water Diving Kit's Ability to Prevent Water Aspiration into the MK 21 MOD 1 UBA

Descriptive Note:

Test rept. Mar-Apr 1994

Corporate Author:

NAVY EXPERIMENTAL DIVING UNIT PANAMA CITY FL

Personal Author(s):

Report Date:

1994-04-01

Pagination or Media Count:

8.0

Abstract:

A contaminated water diving system CWDS protects a diver from exposure to water-borne toxic, volatile, corrosive, or microbial agents. This report followed up on a previous report that evaluated the ability of the Diving Systems, International DSI, Santa Barbara, CA contaminated water diving kit to prevent water aspiration into the MK 21 MOD 1 underwater breathing apparatus UBA. These kits are comprised of double flapper exhaust values and a secondary water dump value. Testing was conducted to a maximum depth of 60.6 msw 198 fsw , using respiratory minute volume RMV levels as high as 90 liters per minute LPM. The performance of the values was continuously monitored using a video camera mounted inside the UBA during testing. The values maintained watertight integrity until the inspiratory pressures produced by the mechanical breathing machine far exceeded those that a diver can produce. Thus, the contaminated water kit provides working divers definitive protection from water aspiration. Therefore, NEDU continues to recommend the DSI contaminated water kit for Navy use in the MK 21 MOD 1 UBA.

Subject Categories:

  • Personnel Management and Labor Relations
  • Stress Physiology

Distribution Statement:

APPROVED FOR PUBLIC RELEASE