Accession Number:

ADA277668

Title:

Integration of the Molecular Sieve Oxygen Generating System (MSOGS) into the UH-60Q Medevac Blackhawk

Descriptive Note:

Final rept. 24 Aug 92-30 May 93,

Corporate Author:

SERV-AIR INC LEXINGTON KY

Report Date:

1994-03-11

Pagination or Media Count:

140.0

Abstract:

A Molecular Sieve Oxygen Generated System MSOGS was integrated in the UH-60Q Medevac Helicopter as part of the requirements of this program. Support equipment for the system operation was also integrated in this effort. Problems such as intake air flow cooling and moisture build-up were addressed. Functional and performance tests were conducted by personnel from United States Army Aeromedical Research Laboratory. As a result of the integration effort a more simple and efficient method of installing the MSOGS unit and its supporting systems will be developed. Emphasis will be on the servicing of the oxygen lines on the field to make the system user friendly

Subject Categories:

  • Aircraft
  • Medicine and Medical Research
  • Logistics, Military Facilities and Supplies

Distribution Statement:

APPROVED FOR PUBLIC RELEASE