Accession Number:

ADA275106

Title:

Performance Evaluation of a 22.5/30 KW 270 Volts Direct Current Generator System

Descriptive Note:

Final rept. Jan 1992-Jan 1993

Corporate Author:

WRIGHT LAB WRIGHT-PATTERSON AFB OH

Personal Author(s):

Report Date:

1993-12-01

Pagination or Media Count:

153.0

Abstract:

This report documents the electrical system performance testing of a 12-pole, wound rotor machine with integral 31 speed increaser and rectifier, 22.530 kW 270 Vdc generator system. The performance testing was accomplished in the generator test facility of the Aerospace Power Division WLPOOC-1. This report also documents WLPOOC-ls Data Acquisition System modified for 270 Vdc test and analysis. Generator system parameters measured include transient responses to load applications and removals, ripple voltages, distortion spectrums, and fault currents. Results were compared to electrical system characteristics specified in MIL-STD-704E.

Subject Categories:

  • Aircraft
  • Electric Power Production and Distribution
  • Electricity and Magnetism

Distribution Statement:

APPROVED FOR PUBLIC RELEASE