Accession Number:

ADA273836

Title:

Dynamic Response of a Compressor Research Facility

Descriptive Note:

Master's thesis,

Corporate Author:

AIR FORCE INST OF TECH WRIGHT-PATTERSON AFB OH

Personal Author(s):

Report Date:

1993-12-01

Pagination or Media Count:

221.0

Abstract:

The response of the Wright Laboratory Compressor Research Facility to a small amplitude, acoustic, sinusoidal disturbance was investigated. The fluid transmission line equations for laminar, one-dimensional flow in a circular duct were solved and verified through a laboratory experiment using a scale model of the facility. The resonant frequencies of the facility were determined for a variety of flow conditions. Techniques for analytically modeling end impedance and flow straightening elements were also studied. The fundamental frequency of the facility was determined to be between 5.5 and 6.5 Hz depending on the flow conditions and geometry configurations specified.

Subject Categories:

  • Hydraulic and Pneumatic Equipment
  • Test Facilities, Equipment and Methods
  • Fluid Mechanics

Distribution Statement:

APPROVED FOR PUBLIC RELEASE