Abstract:

This report has been prepared to summarize a test validation effort for an accelerated life testing model which uses a wide parametric Bayesian Analysis Methodology. Step stress testing was performed on seven 7 Joint Tactical Information Distribution System JTIDS Class 1 synthesizer detector, radio frequency assemblies. Failure data and analyses are provided. The report addresses issues concerning how to demonstrate high reliability Mean-Time- Between-Failure values of 10,000 hours or more on procured Air Force systems without incurring excessive testing costs.