Accession Number:

ADA261227

Title:

Verification of the Theoretical Discharge Coefficient of a Sub-Critical Flow Meter

Descriptive Note:

Corporate Author:

GENERAL ELECTRIC CO EVENDALE OH AIRCRAFT ENGINE GROUP

Personal Author(s):

Report Date:

1990-09-01

Pagination or Media Count:

144.0

Abstract:

The objectives of this program were to study the factors leading to increased errors in sub-critical flow metering, utilize existing theoretical methods to design a new sub-critical flow meter for very high accuracy, predict its discharge coefficient, and then experimentally verify it by calibration with an industry standard critical flow meter. The meter design was typical of that used for modern, lightweight, engine mounted bellmouths, but its size was small enough to allow its calibration in a high accuracy laboratory environment. Thus this program provides a calibration of the theoretical method, and establishes the link between a traceable metering standard and large engine bellmouths whose air flow rates exceed the capacity of any of the worlds calibration facilities.

Subject Categories:

  • Test Facilities, Equipment and Methods
  • Fluid Mechanics

Distribution Statement:

APPROVED FOR PUBLIC RELEASE