Accession Number:
ADA254511
Title:
Development and Installation of a Continuous Water Monitoring Systems for the AEDC
Descriptive Note:
Final rept. Mar 1991-May 1992
Corporate Author:
ES INDUSTRIES BERLIN NJ
Personal Author(s):
Report Date:
1992-08-01
Pagination or Media Count:
47.0
Abstract:
A system to sample and analyze water from Rowland Creek at AEDC for hydrocarbon contaminants has been developed under a Small Business Innovation Research SBIR program contract. The online continuous water monitoring system involves the combination of two gas chromatographs GC. The first instrument combines a gasliquid sparger and a GC. The sparger uses an inert gas, helium, to remove and concentrate volatile organic chemicals which are then sequentially analyzed using a GC. The second gas chromatographic instrument involves the analysis of nonvolatile water samples through direct injection of water.
Descriptors:
Subject Categories:
- Test Facilities, Equipment and Methods
- Water Pollution and Control