Accession Number:

ADA254511

Title:

Development and Installation of a Continuous Water Monitoring Systems for the AEDC

Descriptive Note:

Final rept. Mar 1991-May 1992

Corporate Author:

ES INDUSTRIES BERLIN NJ

Personal Author(s):

Report Date:

1992-08-01

Pagination or Media Count:

47.0

Abstract:

A system to sample and analyze water from Rowland Creek at AEDC for hydrocarbon contaminants has been developed under a Small Business Innovation Research SBIR program contract. The online continuous water monitoring system involves the combination of two gas chromatographs GC. The first instrument combines a gasliquid sparger and a GC. The sparger uses an inert gas, helium, to remove and concentrate volatile organic chemicals which are then sequentially analyzed using a GC. The second gas chromatographic instrument involves the analysis of nonvolatile water samples through direct injection of water.

Subject Categories:

  • Test Facilities, Equipment and Methods
  • Water Pollution and Control

Distribution Statement:

APPROVED FOR PUBLIC RELEASE