DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA193012
Title:
High Temperature Testing of C/C (Carbon/Carbon) Composites
Descriptive Note:
Final rept. Jul 1986-Sep 1987
Corporate Author:
WRIGHT STATE UNIV DAYTON OH
Report Date:
1987-12-12
Pagination or Media Count:
8.0
Abstract:
A high temperature vacuum furnace for across-ply testing of carbon carbon composites has been installed. This furnace has a double-walled water- jacketed vacuum chamber and is equipped with a 30 kVA variable output transformer, semi-automatic vacuum system, a digital temperature controller programmer, a two-color optical pyrometer, various thermocouples, and a digital data acquisition system. This furnace has been installed on an existing Model 1123 Instron and heating to 2200 C has been accomplished. Graphite toolings have been prepared and across-ply tensile testing to 1700 C have been conducted. Keywords Carboncarbon composites, High temperature, Graphite furnace, Across ply strength.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE