Abstract:

This brief evaluation of a Basic Environmental Engineering, Inc. heat recovery incinerator HRI documents and describes several innovative features not found in most other modular HRIs this small. These features and subsystems include waterwall primary combustion chamber pulsed hearths for burning material transport multiple zone control of secondary combustions ash removal subsystem with no moving linkages under water and partial integrated digital controls. The system start-up experience, also well documented, may be considered typical or better than average for many modular HRIs in the last few years.

Subject Categories:

  • Non-electrical Energy Conversion
  • Water Pollution and Control

Distribution Statement:

APPROVED FOR PUBLIC RELEASE