Abstract:

The results of the preliminary hazard analysis on the Laboratory Demonstration Electromagnetic Launcher are described. This analysis was based on system concepts and inherent known hazards. This work has concluded that although serious hazards do exist, a properly designed laboratory and detailed operating plan can ensure personnel safety and minimize the potential for system or component damage.

Subject Categories:

  • Safety Engineering
  • Test Facilities, Equipment and Methods
  • Guns
  • Electricity and Magnetism

Distribution Statement:

APPROVED FOR PUBLIC RELEASE