DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA106569
Title:
Overall Effective Thermal Resistance of Corrugated Fiberboard Containers.
Descriptive Note:
Forest Service research paper,
Corporate Author:
FOREST PRODUCTS LAB MADISON WI
Report Date:
1981-08-01
Pagination or Media Count:
13.0
Abstract:
The overall effective thermal resistance of a corrugated fiberboard container was determined as a function of air velocity and board thickness, and an appropriate design curve is presented. The thermal resistance of the container is treated as a sum of resistances, with individual resistance values presented for the interior interfacial contact resistance, the board resistance, and the exterior boundary resistance. Behavioral differences were found for heating versus cooling at conventional board thicknesses and a possible explanation for this behavior is presented. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE