Cost Assessment for Shielding of C3 Type. Facilities
Descriptive Note:
Final rept. 29 Jan 1979-29 Feb 1980
Corporate Author:
IIT RESEARCH INST CHICAGO IL
Report Date:
1980-03-01
Pagination or Media Count:
123.0
Abstract:
Costs were estimated for four slightly different designs for an all- welded steel envelope shield to protect a C3 facility against high-altitude EMP, and for an alternative shield design using overlapping steel sheets joined by powder-driven pins and with seams arc sprayed with zinc. The all-welded shields are substantially more expensive because of the high cost of MIG welding. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE