Accession Number:

ADA076010

Title:

Performance and DiagNOstics of Lasers Initiated by the Reaction of NO with ClO2,

Descriptive Note:

Corporate Author:

DEFENCE RESEARCH ESTABLISHMENT VALCARTIER (QUEBEC)

Report Date:

1979-09-01

Pagination or Media Count:

25.0

Abstract:

A purely chemical HCl laser employing transverse flow was operated with a maximum multiline output power of 13 W, which represents a chemical efficiency of 8.6 based on the total exothermicity of the pumping reaction. The required nonequilibrium concentration on Cl atoms was generated by the branched-chain reaction of NO with ClO2. Mass spectrometric and absorption spectroscopic measurements of species concentrations in the NOClO2 reaction system showed that the effectiveness of production of the branched chain decreased with increasing total pressure. Author

Subject Categories:

  • Lasers and Masers
  • Atomic and Molecular Physics and Spectroscopy

Distribution Statement:

APPROVED FOR PUBLIC RELEASE