Accession Number:

ADA070969

Title:

Paralleled Power Supplies, A Comparison of Methods of Paralleling Power Supplies with the Method Used in the AEGIS Low-Voltage Power System.

Descriptive Note:

Final rept.,

Corporate Author:

NAVAL OCEAN SYSTEMS CENTER SAN DIEGO CA

Personal Author(s):

Report Date:

1978-10-01

Pagination or Media Count:

32.0

Abstract:

This report was prepared as part of the reliability studies of the AEGIS low-voltage power supply and compares methods of paralleling power supplies to determine the method most suitable for the AEGIS system. The two fundamental methods of paralleling power supplies are the automatic crossover method and masterslave method. The automatic crossover method as two subdivisions 1 automatic crossover method used by AEGIS system and 2 the spoiler resistor method. The masterslave method has three subdivisions 1 master pass element drive 2 master voltage reference and 3 current sense. The degree of current sharing that may be expected from these methods varies and depends on the method and how it was used. The automatic crossover method is characterized by unequal current sharing and closely regulated power supplies however, if regulation can be sacrificed, a degree of current sharing may be achieved. The masterslave method theoretically offers equal current sharing but, because of inescapable component differences, only the current sense method offers a reliable method for achieving this. A comparison of the methods of paralleling power supplies show advantages and disadvantages for each The masterslave method may have a slightly higher individual power supply reliability because of its equal load-sharing characteristics however, this reliability advantage does not consider the additional control circuitry that would reduce reliability.

Subject Categories:

  • Electric Power Production and Distribution
  • Test Facilities, Equipment and Methods
  • Surface-Launched Guided Missiles

Distribution Statement:

APPROVED FOR PUBLIC RELEASE