DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA056321
Title:
Tri-Service Thermal Flash Test Facility.
Descriptive Note:
Interim summary rept. 6 Aug 76-5 Nov 77,
Corporate Author:
DAYTON UNIV OHIO
Report Date:
1978-03-29
Pagination or Media Count:
48.0
Abstract:
This report describes the status and capabilities of the Thermal Nuclear Flash Test Facility which is used for investigating the effects of thermal radiation on materials. The Facility consists of several quartz lamp banks for simulating thermal radiation, a wind tunnel for simulating aerodynamic loads, and a mechanical loading device for simulating tension and binding loads, and associated instrumentation.
Distribution Statement:
APPROVED FOR PUBLIC RELEASE