Accession Number:

ADA056015

Title:

Shield Group 5 Suppressive Shield Plastic Liner and Propellant Testing.

Descriptive Note:

Engineering study Mar 76-May 77,

Corporate Author:

COMPUTER SCIENCES CORP BAY ST LOUIS MISS ENGINEERING AND SCIENCE SERVICES LAB

Personal Author(s):

Report Date:

1978-02-01

Pagination or Media Count:

63.0

Abstract:

A prototype Shield Group 5 Suppressive Shield of modular, prefabricated construction suitable for application to illuminant, propellant and pyrotechnics production lines was used. The testing was to evaluate the performance of plastic and steel liners and to increase the safety certifiable liners for the Group 5SS to 22.7 kg of illuminant, 270 kg of propellant and 1.1 kg of high explosive. Author

Subject Categories:

  • Safety Engineering
  • Structural Engineering and Building Technology
  • Pyrotechnics
  • Explosions

Distribution Statement:

APPROVED FOR PUBLIC RELEASE