Accession Number:

ADA055999

Title:

Repetitive Series Interrupter II

Descriptive Note:

Interim rept. no. 7, 1 Oct 1977-31 Jan 1978

Corporate Author:

EG AND G INC SALEM MA ELECTRONIC COMPONENTS DIV

Report Date:

1978-06-01

Pagination or Media Count:

68.0

Abstract:

The interruption characteristics have been established for six developmental plasma chute interrupters, five rated at 15 kV and one rated at 30 kV. Six-hundred ampere interruptions at 20 kV have been achieved with a magnetic field energy of less than 8 joules. The most efficient interaction channel geometry has been found to be one which contains both a chuted surface against which the discharge is magnetically driven, and an unchuted smooth surface located behind the driven discharge, the presence of which latter surface minimizes the availability of plasma to sustain the discharge. Typical interaction column drops have been found to be 300 to 400 volts per section 20 to 26 voltscm at reasonable tube pressures with no more than three and possibly two sections being adequate for the operation of tubes rated at 50 kV. Holdoff-section voltage drops of about 120 volts have been observed for holdoff sections capable of withstanding 30 kV. A total tube drop of 830 volts has been observed at the 25 kV, 18.5 A level. Linear extrapolation of existing data to the 50 kV, 1000 A level shows that reliable interruption should be achievable with a magnetic field energy of the order of 10 joules for an interrupter having a total tube drop of about 1200 volts, or 2.4 of the systems operating voltage.

Subject Categories:

  • Electrical and Electronic Equipment
  • Plasma Physics and Magnetohydrodynamics

Distribution Statement:

APPROVED FOR PUBLIC RELEASE