Accession Number:

ADA051538

Title:

Destroyer Engineered Operating Cycle (DDEOC) System Maintenance Analysis DDG-37 Class Firemain and Auxiliary Machinery Cooling Water Systems SMA 37-201- 521. Review of Experience

Descriptive Note:

Corporate Author:

ARINC RESEARCH CORP ANNAPOLIS MD

Personal Author(s):

Report Date:

1978-02-01

Pagination or Media Count:

88.0

Abstract:

The goal of the Destroyer Engineered Operating Cycle DDEOC Program is to effect an early improvement in the material condition of ships, at an acceptable cost, while maintaining or increasing their operational availability during an extended operating cycle. In support of this goal, System Maintenance Analyses SMAs are being conducted for selected systems and subsystems of designated surface combatants. The principal element of an SMA is the Review of Experience ROE. This report documents the ROE for the DDG-37 Class Firemain and Auxiliary Machinery Cooling Water Systems. The ROE is an analysis of existing and anticipated problems that affect the operational performance or maintenance program of a ship system. The ROE report serves as a vehicle for assessing the significance and consequences of identified problems. The report also recommends specific actions and a system maintenance policy that will prevent or reduce the impact of problem occurrence while improving material condition and maintaining or increasing system availability throughout an extended ship operating cycle.

Subject Categories:

  • Air Conditioning, Heating, Lighting and Ventilating
  • Marine Engineering
  • Safety Engineering

Distribution Statement: