DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
ADA048986
Title:
Roof Moisture Survey. Ten State of New Hampshire Buildings,
Descriptive Note:
Corporate Author:
COLD REGIONS RESEARCH AND ENGINEERING LAB HANOVER N H
Report Date:
1977-12-01
Pagination or Media Count:
36.0
Abstract:
Ten roofs in Concord, New Hampshire, were surveyed for wet insulation using a hand-held infrared camera. Suspected wet areas were marked on the roof with spray paint and roof samples were obtained to verify wet and dry conditions. Recommendations for maintenance and repair were made based on infrared findings, water contents, and visual examinations. An incremental economic study is presented to serve as a guide in determining the most cost-effective approach. Author
Distribution Statement:
APPROVED FOR PUBLIC RELEASE