Accession Number:

ADA048174

Title:

Calculation of the Per-Unit Length Capacitance Matrix for Shielded Insulated Wires.

Descriptive Note:

Final rept.,

Corporate Author:

SCIENCE APPLICATIONS INC BERKELEY CALIF

Report Date:

1977-09-01

Pagination or Media Count:

30.0

Abstract:

In this report, the per-unit-length capacitance matrix of a multiconductor transmission line enclosed in a shielding tube is calculated using the method of multiseries expansion. Each individual wire may be dielectric coated. The methods of evaluating the corresponding per-unit-length inductance matrix and the propagation matrix are also presented. Author

Subject Categories:

  • Electrical and Electronic Equipment
  • Machinery and Tools
  • Test Facilities, Equipment and Methods

Distribution Statement:

APPROVED FOR PUBLIC RELEASE