Accession Number:

ADA037198

Title:

Radar Microwave Link Pilot System Upgrade and Evaluation.

Descriptive Note:

Final rept.,

Corporate Author:

INSTITUTE FOR TELECOMMUNICATION SCIENCES BOULDER COLO

Personal Author(s):

Report Date:

1976-12-01

Pagination or Media Count:

63.0

Abstract:

Methods of upgrading the existing Radar Microwave Link systems were developed and tested in the laboratory. Replacement of existing klystron and other tube-type components with solid-state units can be expected to provide additional system fade margin and greater system equipment reliability. Author

Subject Categories:

  • Air Navigation and Guidance
  • Active and Passive Radar Detection and Equipment
  • Radio Communications

Distribution Statement:

APPROVED FOR PUBLIC RELEASE