Accession Number:

ADA030373

Title:

Development of an Automated Mustard Stack Monitor. Phase II.

Descriptive Note:

Final rept. Dec 75-Jun 76,

Corporate Author:

TRACOR INC AUSTIN TEX

Personal Author(s):

Report Date:

1976-06-01

Pagination or Media Count:

29.0

Abstract:

The details of design, development and testing of an automated stack analyzer capable of monitoring mustard gas at levels of 0.03 mgcu.m. are given. Operating conditions and analytical procedure are given. Results are described. The Tracor 270HA Atmospheric Analyzer, by several modifications, was transformed into the Model 275HA mustard analyzer, found to give adequate results. Author

Subject Categories:

  • Chemical, Biological and Radiological Warfare

Distribution Statement:

APPROVED FOR PUBLIC RELEASE