Storage Reliability of Missile Materiel Program. Missile Hydraulic and Pneumatic Systems Pump Analysis.

Descriptive Note:

Final rept. Jun 74-Jun 76,

Corporate Author:

RAYTHEON CO HUNTSVILLE ALA LIFE CYCLE ANALYSIS DEPT

Personal Author(s):

Report Date:

1976-05-01

Pagination or Media Count:

54.0

Abstract:

This report documents findings on the non-operating reliability of pumps. The study consists of over 1.2 billion part hours. The sources show storage failure rate for Positive Displacement Pumps, Fixed and Variable, as 380.2 FITS failures per billion hours and 475.0 FITS respectively. It also gives failure rates for Kinetic, 200.0 FITS Hydraulic, 95.3 FITS and Fuel Pumps, 123.9 FITS. Elements of pump design are reviewed. This information is part of a research program being conducted by the U. S. Army Missile Command, Redstone Arsenal, Alabama. The objective of this program is the development of non-operating storage reliability prediction and assurance techniques for missile materiel. Author

Subject Categories:

  • Guided Missile Launching and Basing Support

Distribution Statement:

APPROVED FOR PUBLIC RELEASE