Accession Number:

ADA025481

Title:

Reliability, Availability, and Maintainability Analysis of the LSAAP 105MM Assembly Line.

Descriptive Note:

Final rept.,

Corporate Author:

DARCOM INTERN TRAINING CENTER TEXARKANA TEX

Personal Author(s):

Report Date:

1976-04-01

Pagination or Media Count:

123.0

Abstract:

The reliability, availability, and maintainability RAM characteristics of the 105MM assembly line at Lone Star Army Ammunition Plant LSAAP are evaluated in this paper. The evaluation is based on data observed during an operational test period, conducted from 23 Sep-4 Oct 74. Topics that are discussed in this paper are factors that may have affected the test data, collection of the data, goodness of fit tests, confidence intervals, previous RAM reports, and the calculation of the RAM parameters.

Subject Categories:

  • Manufacturing and Industrial Engineering and Control of Production Systems
  • Ammunition and Explosives

Distribution Statement:

APPROVED FOR PUBLIC RELEASE