Accession Number:

ADA022798

Title:

No-Voltage Meter

Descriptive Note:

Final rept. Oct 1973-Jan 1975

Corporate Author:

NAVAL WEAPONS CENTER CHINA LAKE CA

Personal Author(s):

Report Date:

1976-02-01

Pagination or Media Count:

13.0

Abstract:

A meter with no power source was designed to make voltage checks on firing lines. The meter will detect 50 millivolts, both AC and DC voltages, and cannot result in voltage transfer to the firing line.

Subject Categories:

  • Test Facilities, Equipment and Methods
  • Electricity and Magnetism

Distribution Statement:

APPROVED FOR PUBLIC RELEASE