Accession Number:

ADA017299

Title:

EMP Testing of Buried Conduits, The Pulsed Dipole and Pulsed Transmission Line.

Descriptive Note:

Technical memo.,

Corporate Author:

HARRY DIAMOND LABS ADELPHI MD

Report Date:

1975-09-01

Pagination or Media Count:

14.0

Abstract:

Buried conduit systems form an integral part of the EMP shielding in large hardened missile systems such as SAFEGUARD to protect the communications, control, and power cabling from NEMP effects. To initially verify conduit system hardness and to ensure that it is maintained over the system life, nondestructive testing techniques are being developed to detect and locate their flaws that could adversely affect EMP hardness and to measure their impact on system hardness. Several testing techniques that have been developed are discussed, and experimental data are presented from measurements on buried conduits.

Subject Categories:

  • Electrical and Electronic Equipment

Distribution Statement:

APPROVED FOR PUBLIC RELEASE