Accession Number:

ADA011223

Title:

Development and Evaluation of Repairs for EMP Leaks in Conduit Systems

Descriptive Note:

Final rept.

Corporate Author:

CONSTRUCTION ENGINEERING RESEARCH LAB (ARMY) CHAMPAIGN IL

Report Date:

1975-04-01

Pagination or Media Count:

78.0

Abstract:

The report discusses the development and evaluation of repairs for EMP leaks in conduit systems at the SAFEGUARD site. Repairs for 4-in. explosion-proof conduit unions, communications cable-gripper boxes, and non-RFI tight flexible conduit are studied.

Subject Categories:

  • Electrical and Electronic Equipment
  • Antimissile Defense Systems

Distribution Statement:

APPROVED FOR PUBLIC RELEASE