Accession Number:

ADA009314

Title:

An Evaluation of High Level Noise and Its Reduction in a 3000 BTU/HR Gasoline-Engine-Powered Field Refrigeration Unit.

Descriptive Note:

Final rept.,

Corporate Author:

ARMY MATERIEL COMMAND TEXARKANA TEX INTERN TRAINING CENTER

Personal Author(s):

Report Date:

1975-04-01

Pagination or Media Count:

73.0

Abstract:

The report describes the results of research intended to determine the sources of high level airborne noise transmitted from a 3000 BTUhr mobile refrigeration unit using an air-cooled engine as the prime mover. An electric motor was adapted to power the unit and the major noise producing components of the system compressor, motor, fan were analyzed separately to determine their contribution to the overall noise. Noise measurements with a sound level meter and octave band analyzer indicated the gasoline engine to be the major source of high level noise. A significant reduction of noise levels was accomplished by addition of sound suppression materials and relocation of the engine exhaust outlet. Design changes which would further reduce engine noise emission are recommended for future procurement of the mobile refrigeration unit.

Subject Categories:

  • Air Conditioning, Heating, Lighting and Ventilating
  • Civil Engineering

Distribution Statement:

APPROVED FOR PUBLIC RELEASE