Accession Number:

ADA002321

Title:

RADC SOI Test Facility Upgrade

Descriptive Note:

Final rept. 28 Nov 1972-31 Jul 1974

Corporate Author:

RCA GOVERNMENT SYSTEMS DIV MOORESTOWN NJ MISSILE AND SURFACE RADAR

Report Date:

1974-10-01

Pagination or Media Count:

138.0

Abstract:

The report describes the effort expended in upgrading the Wideband Pulse Compression Radar at the Floyd Test Annex to a 500 MHz bandwidth. The effort consisted of transmitter redesign and overhaul, design, and fabrication of a high speed system synchronizer, design and fabrication of a solid state sweep generator, and the installation and integration into the system of Government supplied equipment from other vendors. The Government furnished equipment included new pulse compression filters, transversal equalizers, pulse compression dispersive delay line assembly, wideband RF front end including RF preamplifiers and several IF amplifiers. The major requirement and major work effort was the achievement of very high system linearity, good stability and RFI avoidance.

Subject Categories:

  • Active and Passive Radar Detection and Equipment

Distribution Statement:

APPROVED FOR PUBLIC RELEASE