DID YOU KNOW? DTIC has over 3.5 million final reports on DoD funded research, development, test, and evaluation activities available to our registered users. Click
HERE to register or log in.
Accession Number:
AD1112550
Title:
Measurement of Mercury Mass in the Deep Space Atomic Clocks (DSAC's) rf-Discharge Lamp
Descriptive Note:
[Technical Report, Technical Report]
Corporate Author:
AEROSPACE CORP
Report Date:
2019-09-01
Pagination or Media Count:
11
Abstract:
Using Differential Scanning Calorimetry DSC, we demonstrate an ability to measure mercury mass in Hg rf-discharge lamps used in space-qualified Hg atomic clocks. In particular, for a DSAC Hg lamp provided by JPL, we measure a mass of 205 15 micro-gms. We believe the mass uncertainty is low enough to allow us to perform Hg consumption studies on these lamps, and through those studies define minimum Hg fills for the lamps to ensure specified space-mission lifetimes. Additionally, we show that photographic images of Hg droplets can provide a rough means of estimating Hg mass in rf-discharge lamps.
Distribution Statement:
[A, Approved For Public Release]