Abstract:

Manufacturers have marketed more esthetic ceramic-based abutment and crown options ranging from leucite and lithium disilicate reinforced glass to polycrystalline materials. Limited laboratory research has been published specifically evaluating combinations of these materials on a titanium-based implant platform. The purpose of this study was to evaluate the fracture strength of titanium-based implant crowns of various restorative and provisional materials.